{"id":7707,"date":"2022-11-03T14:54:53","date_gmt":"2022-11-03T14:54:53","guid":{"rendered":"https:\/\/intrazero.com\/work\/fireandrescuetech\/?page_id=7707"},"modified":"2024-03-12T20:30:00","modified_gmt":"2024-03-12T18:30:00","slug":"decontamination-shower","status":"publish","type":"page","link":"https:\/\/www.fireandrescuetech.com\/index.php\/vetter-decontamination\/decontamination-shower\/","title":{"rendered":"Decontamination Shower"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-page\" data-elementor-id=\"7707\" class=\"elementor elementor-7707\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-7acae0b elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"7acae0b\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-b11c934\" data-id=\"b11c934\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-b9c7413 elementor-widget elementor-widget-heading\" data-id=\"b9c7413\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-large\">Decontamination Shower<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-dd2745f elementor-widget elementor-widget-text-editor\" data-id=\"dd2745f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The pneumatic decontamination showers are set up in just 40 seconds and are instantly operational. They are used as emergency decontamination positions or applied in combination with tents.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1d6e394 align-left elementor-widget elementor-widget-mae-button\" data-id=\"1d6e394\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"mae-button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\n        <a class=\"master-button btn-accent icon-left medium\" href=\"https:\/\/www.fireandrescuetech.com\/index.php\/request-a-qoute\/\" target=&quot;_blank&quot; >\n            <span class=\"icon \"><\/span>            <span>Request A Quote<\/span>\n                    <\/a>\n\n        \t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-0f1dbde\" data-id=\"0f1dbde\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-928a355 elementor-arrows-position-inside elementor-widget elementor-widget-image-carousel\" data-id=\"928a355\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;slides_to_show&quot;:&quot;1&quot;,&quot;navigation&quot;:&quot;arrows&quot;,&quot;autoplay&quot;:&quot;yes&quot;,&quot;pause_on_hover&quot;:&quot;yes&quot;,&quot;pause_on_interaction&quot;:&quot;yes&quot;,&quot;autoplay_speed&quot;:5000,&quot;infinite&quot;:&quot;yes&quot;,&quot;effect&quot;:&quot;slide&quot;,&quot;speed&quot;:500}\" data-widget_type=\"image-carousel.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-image-carousel-wrapper swiper\" role=\"region\" aria-roledescription=\"carousel\" aria-label=\"Image Carousel\" dir=\"ltr\">\n\t\t\t<div class=\"elementor-image-carousel swiper-wrapper\" aria-live=\"off\">\n\t\t\t\t\t\t\t\t<div class=\"swiper-slide\" role=\"group\" aria-roledescription=\"slide\" aria-label=\"1 of 9\"><figure class=\"swiper-slide-inner\"><img decoding=\"async\" class=\"swiper-slide-image\" src=\"https:\/\/www.fireandrescuetech.com\/wp-content\/uploads\/2022\/11\/1513001801_600x600.jpg\" alt=\"Decontamination tent PZ 17 2 L\" \/><\/figure><\/div><div class=\"swiper-slide\" role=\"group\" aria-roledescription=\"slide\" aria-label=\"2 of 9\"><figure class=\"swiper-slide-inner\"><img decoding=\"async\" class=\"swiper-slide-image\" src=\"https:\/\/www.fireandrescuetech.com\/wp-content\/uploads\/2022\/11\/1513001801-Dekondusche.jpg\" alt=\"Decontamination tent PZ 17 2 L\" \/><\/figure><\/div><div class=\"swiper-slide\" role=\"group\" aria-roledescription=\"slide\" aria-label=\"3 of 9\"><figure class=\"swiper-slide-inner\"><img decoding=\"async\" class=\"swiper-slide-image\" src=\"https:\/\/www.fireandrescuetech.com\/wp-content\/uploads\/2022\/11\/Dekon-Dusche-2-scaled.jpg\" alt=\"Decontamination tent PZ 17 2 L\" \/><\/figure><\/div><div class=\"swiper-slide\" role=\"group\" aria-roledescription=\"slide\" aria-label=\"4 of 9\"><figure class=\"swiper-slide-inner\"><img decoding=\"async\" class=\"swiper-slide-image\" src=\"https:\/\/www.fireandrescuetech.com\/wp-content\/uploads\/2022\/11\/Dekon-Dusche-3-1.jpg\" alt=\"Decontamination tent PZ 17 2 L\" \/><\/figure><\/div><div class=\"swiper-slide\" role=\"group\" aria-roledescription=\"slide\" aria-label=\"5 of 9\"><figure class=\"swiper-slide-inner\"><img decoding=\"async\" class=\"swiper-slide-image\" src=\"https:\/\/www.fireandrescuetech.com\/wp-content\/uploads\/2022\/11\/Dekon-Dusche-scaled.jpg\" alt=\"Decontamination tent PZ 17 2 L\" \/><\/figure><\/div><div class=\"swiper-slide\" role=\"group\" aria-roledescription=\"slide\" aria-label=\"6 of 9\"><figure class=\"swiper-slide-inner\"><img decoding=\"async\" class=\"swiper-slide-image\" src=\"https:\/\/www.fireandrescuetech.com\/wp-content\/uploads\/2022\/11\/Dekondusche-scaled.jpg\" alt=\"Decontamination tent PZ 17 2 L\" \/><\/figure><\/div><div class=\"swiper-slide\" role=\"group\" aria-roledescription=\"slide\" aria-label=\"7 of 9\"><figure class=\"swiper-slide-inner\"><img decoding=\"async\" class=\"swiper-slide-image\" src=\"https:\/\/www.fireandrescuetech.com\/wp-content\/uploads\/2022\/11\/Dekondusche_2-scaled.jpg\" alt=\"Decontamination tent PZ 17 2 L\" \/><\/figure><\/div><div class=\"swiper-slide\" role=\"group\" aria-roledescription=\"slide\" aria-label=\"8 of 9\"><figure class=\"swiper-slide-inner\"><img decoding=\"async\" class=\"swiper-slide-image\" src=\"https:\/\/www.fireandrescuetech.com\/wp-content\/uploads\/2022\/11\/Dekonduschen-1-scaled.jpg\" alt=\"Vetter Outdoorshooting Zelt, Dusche - April 2013 - Foto: Tim Upietz\" \/><\/figure><\/div><div class=\"swiper-slide\" role=\"group\" aria-roledescription=\"slide\" aria-label=\"9 of 9\"><figure class=\"swiper-slide-inner\"><img decoding=\"async\" class=\"swiper-slide-image\" src=\"https:\/\/www.fireandrescuetech.com\/wp-content\/uploads\/2022\/11\/Doppeldekondusche_3-scaled.jpg\" alt=\"Decontamination tent PZ 17 2 L\" \/><\/figure><\/div>\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"elementor-swiper-button elementor-swiper-button-prev\" role=\"button\" tabindex=\"0\">\n\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"eicon-chevron-left\"><\/i>\t\t\t\t\t<\/div>\n\t\t\t\t\t<div class=\"elementor-swiper-button elementor-swiper-button-next\" role=\"button\" tabindex=\"0\">\n\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"eicon-chevron-right\"><\/i>\t\t\t\t\t<\/div>\n\t\t\t\t\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-ce76fa6 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"ce76fa6\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-4a17f31\" data-id=\"4a17f31\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-69313b1 elementor-widget elementor-widget-text-editor\" data-id=\"69313b1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The showers are constructed so that, due to their size, they can be easily and quickly integrated into the tents. Consequently, the functional radius is extended by a clothing changing area. In addition to this, the decon shower has an additional frontal outside the basin. This capability enables subsequent cleaning of boots and avoids any splashing of contaminated water on the floor.<\/p><ul><li>Shower curtain and the insertion basin are exchangeable<\/li><li>Raised support frame for feet positioning (ergonomic position)<\/li><li>Abrasion protection on the underside<\/li><li>Shower hose is exchangeable<\/li><li>8 moveable shower heads positioned at different heights<\/li><li>Facility for additional fitting of a decontamination hand shower<\/li><\/ul><p>IN OPERATION<\/p><ul><li>Epidemics<\/li><li>Decontamination of patients in front of hospitals<\/li><li>Decontamination lines<\/li><li>Terror attacks or events of war<\/li><li>Personnel or patient shower in mobile hospitals<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-e973b6e elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"e973b6e\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-434cc36\" data-id=\"434cc36\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-9c9f919 elementor-align-left elementor-widget elementor-widget-button\" data-id=\"9c9f919\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/www.fireandrescuetech.com\/wp-content\/uploads\/2022\/11\/Decon_shower.pdf\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t<span class=\"elementor-button-icon\">\n\t\t\t\t<i aria-hidden=\"true\" class=\"fe fe-arrow-right\"><\/i>\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Download PDF<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Decontamination Shower The pneumatic decontamination showers are set up in just 40 seconds and are instantly operational. They are used as emergency decontamination positions or applied in combination with tents. Request A Quote The showers are constructed so that, due to their size, they can be easily and quickly integrated<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":7229,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-7707","page","type-page","status-publish","hentry"],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/www.fireandrescuetech.com\/index.php\/wp-json\/wp\/v2\/pages\/7707","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.fireandrescuetech.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.fireandrescuetech.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.fireandrescuetech.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.fireandrescuetech.com\/index.php\/wp-json\/wp\/v2\/comments?post=7707"}],"version-history":[{"count":32,"href":"https:\/\/www.fireandrescuetech.com\/index.php\/wp-json\/wp\/v2\/pages\/7707\/revisions"}],"predecessor-version":[{"id":10158,"href":"https:\/\/www.fireandrescuetech.com\/index.php\/wp-json\/wp\/v2\/pages\/7707\/revisions\/10158"}],"up":[{"embeddable":true,"href":"https:\/\/www.fireandrescuetech.com\/index.php\/wp-json\/wp\/v2\/pages\/7229"}],"wp:attachment":[{"href":"https:\/\/www.fireandrescuetech.com\/index.php\/wp-json\/wp\/v2\/media?parent=7707"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}